Key Features
COMPOSITE STRUCTURE
Is flexible and durable unlike other shelters. Radius Shelters have no basement feeling, no tin can feeling, and not a retrofitted tank. Our structures are designed as high pressure composite underground structures. Radius shelters have a life span of over 250 years, no corrosion inside or outside, no condensation inside the shelter like steel tanks, and the shelter inside surface is always bright white.
_______________________________________________________________________________
DESIGN
Radius shelters are compound curved shapes with no catastrophic failure mode like round tanks. Radius shelters have no flat walls and no tensile loads. Radius shelters are specifically designed for external pressures and ground shock far exceeding 8.5 Richter and can be placed in high water tables without tie-downs to produce concentrated stresses. The sealed composite shell keeps out radon gas as well as bugs and water.
_______________________________________________________________________________
COMMERCIAL MILITARY PRODUCT
Radius Engineering International Inc. is a United States Department of Defense Contractor and our products are ITAR (International Trade Arms Regulated) and listed on the USML (United States Munitions List). Things that defend against a weapon system are classified the same as the weapon system.
_______________________________________________________________________________
CONSTANT HULL PRESSURE RATING
Radius Shelters have a constant pressure rating that does not have to be de-rated each year due to corrosion like steel structures. The walls of all Radius shelters are designed with an outward curve making the structure extremely strong and providing a much better atmosphere for claustrophobic shelterists. Radius shelters range in rating from 15 psi (1.5 miles from Ground Zero of a 1 MT nuclear weapon) to 40 psi (1 mile from GZ of a 1 MT nuclear weapon) external pressure in addition to the earth static load and does not depend on earth arching. Shelters exposed to more than 40 psi require seatbelts.
_______________________________________________________________________________
RADIATION SHIELDING
Radius shelters have angled entranceways to reduce radiation entering the shelter to a safe level. All entranceway radiation transport geometry complies with PRINCIPLES OF PROTECTION , The US Handbook of Shelter Design Engineering Standards, 2002 and 2011. The standard earth cover over all Radius shelters is 8.5 ft of earth. The maximum radiation dose in any Radius shelter through both the entranceway and from overhead is based on a 1 MT surface burst and a 500 KT air burst which results in a maximum lifetime radiation dose inside the shelter from initial gamma radiation, gamma radiation, and neutron radiation of less than 1 REM (The same as a chest X-Ray).
_______________________________________________________________________________
STEALTH
Radius composite structures have no radar signature, minimal thermal signature, and with 8.5' of dirt above them are hard to find with ground penetrating radar. Camouflage and landscaping limit detection by digital imagery systems and direct observation.
_______________________________________________________________________________
ENTRANCEWAYS
Radius shelters are entered by conventional stairwells, spiral stairwells, ramps for the handicapped, tunnel ramps for vehicles, and various emergency escape tunnels.
_______________________________________________________________________________
SEISMIC JOINTS
All connections from entranceways to the shelter and between shelters have a seismic joints allowing flexing during ground shock and normal earth movement.
_______________________________________________________________________________
INTERNAL SHELTER PRESSURE
Radius shelters exposed to a blast control the shelter internal pressure by Overpressure Choking so there are no moving parts. No obsolete technology using cumbersome blast valves that require maintenance and can get clogged by rodents and insects.

_______________________________________________________________________________
EMP PROTECTION
The Radius shelter hulls are made of T2 Conductive Composite eliminating the conventional problems associated with corrosion.
Radius Shelters are also powered by internal generators to operate entirely "off the grid" so there is no risk of damage to internal equipment from EMP collected on grid power.
_______________________________________________________________________________
SHELTER HISTORY
Radius has a 32 year shelter engineering and manufacturing history which started with concrete and steel shelters and over a period of years evolved to composite high pressure structures as the market demanded better performance for underground structures.

_______________________________________________________________________________
FOOD STORAGE BEAMS
Radius Shelters can be supplied with optional Food Storage Beams that are extremely efficient and store large amounts of food under the second or third story floor and also provide a structural clear span beam. Space within walls and other structural elements can also be used for storage.
_______________________________________________________________________________
AIR FILTRATION
Radius shelters use a patented Nuclear-Biological-Chemical air filtration process called MCAS. The Multiple Chamber Air Sterilization filtration system is composed of a HEPA filter, activated carbon filter, TEDA carbon filter, and Ultraviolet Sterilization chamber producing a kill rate many times that required to kill molds, bacteria, and viruses. Air volumes range from 120 to 600 cfm depending on the blower. The filter elements are visible and can be easily changed and chemical warfare agents can be detected with this system without exiting the shelter. The Radius MCAS air filtration system supplies filtered breathing air for people and for the generator at a minimum of 15 cubic feet per minute per shelterist. The normal breathing rate for an adults human is 0.33 cfm (cubic feet per minute).
_______________________________________________________________________________
INTERNAL DIESEL GENERATOR
Radius shelters have internal quiet slow speed diesel generators providing power for 6 months to 5 years off the local power grid. Fuel tanks are made of special structural fiberglass located inside the shelter for leak detection. Fungicides and circulating pumps maintain the fuel. All air entering the shelter is filtered including generator cooling and combustion air. Generator exhaust is mixed with cooling air and diffused over a large area at the surface to minimize the thermal signature. The generators are operating in a composite structure and shielded from EMP by 8.5 feet of earth.
_______________________________________________________________________________
SECRECY
Secrecy is essential to keep from having to defend the shelter from intruders after a disaster and worse intruders may get to the shelter before the members if the location is known. Radius Shelters are temporary emergency structures having no foundation and no connection to local services therefore building permits for those things are not required (Permits are posted for public inspection). Earthcom structures have no concrete foundations or slab so there is no cure time installing a shelter. Radius shelters are installed by the Radius installer Green Eye Technology. No local contractors are used for the installation. Under the Second Amendment of the United States Constitution, US citizens are have a right to bear arms and protect themselves from threats but the 1978 War Powers Act gives local, state, and federal governments the right to commandeer any supplies for the benefit of public good during times of disaster and they have a right to use "limited force" to secure necessary supplies.
_______________________________________________________________________________
HATCH AT GROUND LEVEL
Radius shelters have a hydraulic/manual hatch operation capable of lifting 10,000 pounds of debris off of the hatch. The hatch at ground level is made of Combat CompositeTM for various levels of bullet resistance from Class I to Class IV NIJ standards and designed to resist seven basic intruder assaults.
_______________________________________________________________________________
INSIDE SURFACE
Radius shelters have a smooth sanitary closed pore inside surface that can be easily maintained in a sanitary condition with almost any cleaning solution. The composite laminate has a Flame Spread of Class II under ASTM E 84 similar to epoxy coatings and shown above under the direct flame of a torch for 20 minutes.
_______________________________________________________________________________
LIGHTING
Radius shelters have LED lights with very low power consumption, very low heat generation, and over 50,000 hr average life. Lighting levels allow reading in all living areas inside the shelter.
_______________________________________________________________________________
ELECTRICAL SYSTEMS
Radius shelters have both 12 VDC and 120 VAC electrical systems (larger shelters have 220VAC). Battery banks store electrical energy and are maintained by an smart inverter/charger powered by the diesel generator. There are separate circuit breaker panels for AC and DC and all wiring conforms to the NEC and/or ABYC codes.
_______________________________________________________________________________
PLUMBING SYSTEM
Radius shelters have conventional high pressure water systems, water filters, showers, kitchen sinks, bathroom sinks, toilet with a sewage lift station, and high pressure fiberglass leaching septic tanks conforming to conventional leach field standards. Water is usually supplied by a dedicated well but water tanks and other supply systems are available.
_______________________________________________________________________________
COMMUNICATIONS
Radius shelters come with a scanner to listen to what is going on outside and HAM radio to call for help if needed. The antennas are erected from inside the shelter after the disaster has passed. Various camouflaged surface mounted video observation systems are available.
_______________________________________________________________________________
APPLIANCES
Radius shelters have 120VAC wiring for appliances and consumer electronics. The larger shelters have 220VAC wiring and can power larger appliances like water heaters and full size dryers.
_______________________________________________________________________________
GROWING FLOWERS AND FOOD
Radius shelters can be equipped with hydroponic and/or conventional growing systems. Larger shelters support aquaculture and farm animals to supplement the shelterist's diet.
_______________________________________________________________________________
FLOOR PLANS
Radius shelters have standard floor plans but all can be customized. Floor plans typically include apartments, common areas, storage, food preparation, and exercise areas. Larger shelters have room for everything - offices, sick bay, animal treatment room, secure storage, restaurants, meeting rooms, crafts rooms, laboratories, swimming pool, half court basketball, putting green, vehicle and aircraft maintenance areas. All floor plans and facilities are designed in-house by our professional engineering and design departments.
_______________________________________________________________________________
DELIVERY
Radius shelters are delivered by the a Radius truck and special trailer which does not require a Bill Of Lading so there is no paper trail to the installation site. All equipment delivered to site is by Radius truck.
_______________________________________________________________________________
STORAGE
Radius shelters have storage volumes for 6 months to 5 years of food and other supplies. Storage for fuel, grain, fish food, for the same amount of time is designed into the shelter.
_______________________________________________________________________________
PROTECTION COST
Radius shelter protection for a completed and installed project including the product, delivery and installation ranges from $17,000 per shelterist to $80,000 per shelterist depending on the model, duration, interior trim level, site access, volume/shelterist, and life style required in the shelter. Customers are responsible for food, clothing, and personal items to make the shelter ready.
_______________________________________________________________________________
SHELTER COOP AGREEMENT
For large shelter systems, Radius works with the customer group to develop a Not For Profit Underground Shelter Co-Op Agreement where ownership or membership of the community shelter is defined. This agreement includes legal ownership and rights and all policies inside the shelter that shelterists agree to operate under before and after a disaster.
_______________________________________________________________________________
STATE OF THE ART ENGINEERING FOR LIFE
Radius Engineering International® Inc. shelters represent the ultimate "STATE OF THE ART" technology providing NBC protection for private, medical, military, and corporate installations in every state in the US and many countries. All the above key features have made Radius Engineering® International the largest underground shelter manufacturer in the world.